USAfixTM - Repair Guide (RG) - Master Email RG
- Check solenoid output for flow
 Level of Difficulty - MEDIUM  Estimated Completion Time - 30 minutes
TASKI - FG 2C

Tools Required
Tool 
Nut driver-metric 7mm
Screwdriver-phillips

Parts Required


Step Procedure & Parts & Tools
1 LAY THE MACHINE DOWN SO THE FRONT COVER IS FACING UP. REST THE MACHINE ON BOARDS SO THAT THE FILTER ON THE BACK DOESNT GET BROKEN.

2 REMOVE THE 4 SCREWS AND LIFT UP ON THE FRONT COVER TO REMOVE IT.
Screwdriver-phillips

3 LOCATE THE COMPRESSOR AT THE BOTTOM OF THE MACHINE.

4 HOLD THE 3 SCREWS IN PLACE WITH YOUR HAND AND TURN THE NUT DRIVER TO REMOVE THE SCREWS.
Nut driver-metric 7mm

5 SET THE COMPRESSOR ASIDE FOR EASIER ACCESS TO THE SOLENOID VALVE HOSE. DO NOT DISCONNECT THE HOSE OR ANY WIRING.

6 PULL THE BOTTOM HOSE OFF OF THE SOLENOID VALVE.

7 PLUG THE MACHINE IN AND TURN IT ON. IF SOLUTION COMES OUT THE BOTTOM OF THE SOLENOID VALVE, THE SOLENOID VALVE IS OKAY. TURN THE MACHINE OFF.

8 IF SOLENOID VALVE IS OKAY, REVERSE STEPS 1 THRU 6 TO REASSEMBLE THE MACHINE.